• RoHS l'attestation de SJTW, Câbles conformes aux normes UL et/au CSA
  • REACH l'attestation de SJTW, Câbles conformes aux normes UL et/au CSA
  • cULus LISTED l'attestation de SJTW, Câbles conformes aux normes UL et/au CSA
  • CE l'attestation de SJTW, Câbles conformes aux normes UL et/au CSA

SJTW

Flexile cULus approved cables, with enhanced water and UV resistance. Suitable for outdoor use and wet applications.

CABLE STRUCTURE

  • Flexible stranded conductor with electrolytic bare copper.
  • Insulation with high heat resistance special PVC conforming to Class 7 of Table 8 of standard UL 62.
  • The length of lay of cable assembly complies with UL 62 requirements.
  • Outer sheath with special PVC compound  with high heat and water resistance (conforming to Class 1.8 of Table 11 of standard UL 62), suitable for UV exposure and wet installations. Color on customer’s request, according to RAL table
  • Marking : SALCAVI TECHNIC SPA ITALY SJTW No. of conductors X AWG size (mm2 size) 300V 105°C VW-1 (UL)c(UL) E212322 - 40°C   WATER RESISTANT 60°C  MONTH/YEAR.

Câbles conformes aux normes UL et/au CSA: SJTW

APPLICATIONS

Water resistant PVC flexible cables designed for wiring of small appliances equipment and, more generally, of all devices that have to operate outdoor (gardening tools, shop-vacs, weed whackers, etc.)

  • Tension nominale

    Tension nominale
    300 VAC

  • Tension d'essai

    Tension d'essai
    3000 V

  • Température de court-circuit

    Température de court-circuit
    160°C

  • Température d'utilisation

    Température d'utilisation
    - 40 ÷ 105 °C ( @ fixed installations ), - 20 ÷ 105 °C (for dynamic installations )

  • Rayon de courbure minimum

    Rayon de courbure minimum
    ≥ 8 x D ( @ fixed installations ), ≥ 12 x D ( for dynamic installations )

  • Water resistance

    Water resistance
    UL 62 and CSA C22.2 No. 49 clauses 5.2.2, 5.2.4.1, 5.2.4.2, 5.2.3

  • UV resistance

    UV resistance
    UL 62 and CSA C22.2 No. 49 clauses 5.1.6, 5.1.7

  • cULus LISTED

    cULus LISTED
    UL file No. E212322

  • Weather resistance

    Weather resistance
    UL 62 and CSA C22.2 No. 49 clauses 5.1.6, 5.1.7

Des produits similaires à: SJTW