• RoHS l'attestation de SJOOW, Câbles pour applications spéciales
  • REACH l'attestation de SJOOW, Câbles pour applications spéciales
  • cULus LISTED l'attestation de SJOOW, Câbles pour applications spéciales
  • CE l'attestation de SJOOW, Câbles pour applications spéciales

SJOOW

Rubber service cords with (UL) + c(UL) LISTED approvals. They are resistant to oils, water, UV exposure and suitable for outdoor and hard usages and wet installations.

CABLE STRUCTURE

  • Electrolytic flexible bare copper conductor conforming to UL 62 and UL 1581 requirements.
  • EPDM elastomeric rubber conforming to Class 3 of Table 8 of standard UL 62 and resistant to oil contact up to 60°C.
  • The inner cores are twisted together with length of lay conforming to Table 10 of UL 62 standard, wherever it is necessary together with a polyester filler
  • Separator tape.
  • CPE elastomeric rubber conforming to Class 1.4 of Table 11 of standard UL 62, water resistant and oils resistant up to 60°C.
  • Ink-printing : SALCAVI TECHNIC SPA ITALY  SJOOW  No. of conductors X AWG size  90°C  300V FT2 (UL) c(UL) E212322  MM/YY  –40°C WATER RESISTANT

Câbles pour applications spéciales: SJOOW
APPLICATIONS

These jacketed service cords are used for indoor and outdoor electrical power connections requiring high flexibility and time durability and are suitable for both wet and dry locations. They offer an excellent resistance to heat,  oils, water, ozone besides of sunlight, chemicals and abrasion. Typical heavy-duty applications where their use is required include wiring for industrial machinery, large appliances, temporary supply of electrical power and lighting for construction sites. They are often used also in portable equipment and appliances, power extension, small motors and associated machinery.

  • Tension nominale

    Tension nominale
    300 VAC

  • Tension d'essai

    Tension d'essai
    3000 VAC

  • Température d'utilisation

    Température d'utilisation
    - 40 ÷ 90 °C ( @ fixed and dry installation) ; - 20 ÷ 90 °C ( for dynamic applications)

  • Température de court-circuit

    Température de court-circuit
    200 °C

  • UV resistance

    UV resistance
    UL 62 and CSA C22.2 No. 49, Clauses 5.1.1, 5.1.2, 5.1.7 ; UL 2556 and CSA C22.2 No. 2556, Clause 4.2

  • Water resistance

    Water resistance
    UL 62 and CSA C22.2 No. 49, Clauses 5.2.4.1 and 5.2.4.2 ; UL 2556 clauses 6.5, 6.6

  • Oil resistance

    Oil resistance
    UL 62 and CSA C22.2 No. 49 Clauses 5.1.1, 5.1.2 ; UL 2556 and CSA C22.2 No. 2556, Clause 4.2

  • cULus LISTED

    cULus LISTED
    UL File No. E212322

  • Weather resistance

    Weather resistance
    UL 62 and CSA C22.2 No. 49, Clause 5.1.6 ; UL 2556 and CSA C22.2 No. 2556, Clause 7.5

  • Rayon de courbure minimum

    Rayon de courbure minimum
    ≥ 6 x D ( @ fixed installation, @ 20°C) ≥ 8 x D ( for dynamic applications, @ 20°C )

Des produits similaires à: SJOOW
Nous vous proposons une sélection d'autres Câbles pour applications spéciales qui pourraient vous intéresser