• RoHS certification of SJOOW cables, Cables for Special Applications
  • REACH certification of SJOOW cables, Cables for Special Applications
  • cULus LISTED certification of SJOOW cables, Cables for Special Applications
  • CE certification of SJOOW cables, Cables for Special Applications

SJOOW cables

Rubber service cords with (UL) + c(UL) LISTED approvals. They are resistant to oils, water, UV exposure and suitable for outdoor and hard usages and wet installations.

CABLE STRUCTURE

  • Electrolytic flexible bare copper conductor conforming to UL 62 and UL 1581 requirements.
  • EPDM elastomeric rubber conforming to Class 3 of Table 8 of standard UL 62 and resistant to oils contact up to 60°C.
  • The inner cores are twisted together with length of lay conforming to Table 10 of UL 62 standard, wherever it is necessary together with a polyester filler
  • Separator tape.
  • CPE elastomeric rubber conforming to Class 1.4 of Table 11 of standard UL 62, water resistant and oils resistant up to 60°C.
  • Ink-printing : SALCAVI TECHNIC SPA ITALY SJOOW No. of conductors X AWG size 90°C 300V FT2 (UL)c(UL) E212322 –40°C WATER RESISTANT 60°C  OIL RESISTANT 60°C  MONTH/YEAR

Cables for Special Applications: SJOOW cables
APPLICATIONS

These jacketed service cords are used for indoor and outdoor electrical power connections requiring high flexibility and time durability and are suitable for both wet and dry locations. They offer an excellent resistance to heat,  oils, water, ozone besides of sunlight, chemicals and abrasion. Typical heavy-duty applications where their use is required include wiring for industrial machinery, large appliances, temporary supply of electrical power and lighting for construction sites. They are often used also in portable equipment and appliances, power extension, small motors and associated machinery.

  • Short-circuit temperature

    Short-circuit temperature
    200 °C

  • Rated temperature

    Rated temperature
    - 40 ÷ 90 °C ( @ fixed and dry installation) ; - 20 ÷ 90 °C ( for dynamic applications)

  • Rated voltage

    Rated voltage
    300 VAC

  • Water resistance

    Water resistance
    UL 62 and CSA C22.2 No. 49, Clauses 5.2.4.1 and 5.2.4.2 ; UL 2556 clauses 6.5, 6.6

  • UV resistance

    UV resistance
    UL 62 and CSA C22.2 No. 49, Clauses 5.1.1, 5.1.2, 5.1.7 ; UL 2556 and CSA C22.2 No. 2556, Clause 4.2

  • Oil resistance

    Oil resistance
    UL 62 and CSA C22.2 No. 49 Clauses 5.1.1, 5.1.2 ; UL 2556 and CSA C22.2 No. 2556, Clause 4.2

  • cULus LISTED

    cULus LISTED
    UL File No. E212322

  • Weather resistance

    Weather resistance
    UL 62 and CSA C22.2 No. 49, Clause 5.1.6 ; UL 2556 and CSA C22.2 No. 2556, Clause 7.5

  • Minimum bending radius

    Minimum bending radius
    ≥ 6 x D ( @ fixed installation, @ 20°C) ≥ 8 x D ( for dynamic applications, @ 20°C )

  • Test voltage

    Test voltage
    3000 VAC