• RoHS certification of SOOW cables, UL and/or CSA Approved Cables
  • REACH certification of SOOW cables, UL and/or CSA Approved Cables
  • cULus LISTED certification of SOOW cables, UL and/or CSA Approved Cables
  • CE certification of SOOW cables, UL and/or CSA Approved Cables

SOOW cables

Rubber service cords with (UL) + c(UL) LISTED approvals. They are resistant to oils, water, UV exposure and suitable for outdoor and extra hard usages and water immersion up to 10 meters.

CABLE STRUCTURE

  • Electrolytic flexible bare copper conductor conforming to UL 62 and UL 1581 requirements.
  • EPDM elastomeric rubber conforming to Class 3 of Table 8 of standard UL 62 and resistant to oils contact up to 60°C.
  • The inner cores are twisted together with length of lay conforming to Table 10 of UL 62 standard, wherever it is necessary together with a polyester filler
  • Separator tape.
  • CPE elastomeric rubber conforming to Class 1.4 of Table 11 of standard UL 62, water resistant and oils resistant up to 60°C.
  • Ink-printing : SALCAVI TECHNIC SPA ITALY SOOW No. of conductors X AWG size 90°C 600V FT2 (UL)c(UL) E212322 –40°C WATER RESISTANT 60°C OIL RESISTANT 60°C MONTH/YEAR

UL and/or CSA Approved Cables: SOOW cables

APPLICATIONS

SOOW rubber cords are robust, tough and widely used in a number of industrial and construction area and everywhere long life cables are required. They resist oils, water, ozone, aging, and abrasion and are designed for extra hard usage on industrial equipment, heavy tools, battery chargers, portable lights, power extensions. They are also  recommended for mining applications, control systems in industrial plants, steel mills, process facilities and construction sites,  machine and power tools, cranes and dockside power applications or where water immersion is required.

  • Rated voltage

    Rated voltage
    600 VAC

  • Short-circuit temperature

    Short-circuit temperature
    200 °C

  • Rated temperature

    Rated temperature
    - 40 ÷ 90 °C ( in posa fissa, per installazioni asciutte ; - 20 ÷ 90 °C ( per applicazioni dinamiche)

  • Test voltage

    Test voltage
    6 kV

  • Water resistance

    Water resistance
    UL 62 and CSA C22.2 No. 49, Clauses 5.2.4.1 and 5.2.4.2 ; UL 2556 clauses 6.5, 6.6

  • Oil resistance

    Oil resistance
    UL 62 and CSA C22.2 No. 49 Clauses 5.1.1, 5.1.2 ; UL 2556 and CSA C22.2 No. 2556, Clause 4.2

  • UV resistance

    UV resistance
    UL 62 and CSA C22.2 No. 49, Clauses 5.1.1, 5.1.2, 5.1.7 ; UL 2556 and CSA C22.2 No. 2556, Clause 4.2

  • cULus LISTED

    cULus LISTED
    UL File No. E212322

  • Weather resistance

    Weather resistance
    UL 62 and CSA C22.2 No. 49, Clause 5.1.6 ; UL 2556 and CSA C22.2 No. 2556, Clause 7.5

  • Minimum bending radius

    Minimum bending radius
    ≥ 8 x D ( @ fixed installation, @ 20°C), ≥ 10 x D ( for dynamic applications, @ 20°C )

Similar products to: SOOW cables
Here's a selection of other products in UL and/or CSA Approved Cables you may be interested in